TTRF-70(NLT-PC) 3x16+1X16 R100

Description

Description

Application

In apparatus or equipment subject to movement, winding or vibrations and in all type of mobile equipment.

STANDARDS

PRODUCT

NTP 370.250; NTP 370.252; IEC 60227-5; IEC 60227-1

TEST

IEC 60227-2; IEC 60332-1-2; UL 2556; IEC 60811-401; IEC 60811-409; IEC 60811-504; 
IEC 60811-505; IEC 60811-506; IEC 60811-508; IEC 60811-509

CONSTRUCTION

1. Conductor: Flexible soft copper, class 5.

2. Insulation: Flexible compound polyvinyl chloride PVC.

3. Insulated grounding conductor: Flexible copper, class 5 - Compound polyvinyl chloride PVC flexible.

4. Filler: Flexible compound polyvinyl chloride PVC.

5. Outer sheath: Flexible compound polyvinyl chloride PVC.

MAIN CHARACTERISTICS

Great flexibility, compact termination, resistance to abrasion and moisture. Flame retardant. White tag on the sheath where the user can write on it to identify the use of the cable. Sunlight resistance.

GAUGE

16 AWG and 14 AWG.

MARKING

Legible Printed Marking: PERU INDECO BY NEXANS TTRF-70(NLT-PC) - (Nb cores x gauge) + (Ground Cond. Section) 60227 IEC53  300/500V (YEAR) "- (SEQUENTIAL) 0.5m. || (SEQUENTIAL) 0.5 m. +."

PACKING

In 100-meter standard coils or non returnable wooden reels.

COLOUR

Insulation: See core identification.

Outer sheath: Black with traces (number of traces in function on the number of phases, color of traces according to identification of the gauge).

PRODUCT STANDARDS

NTP 370.250: Conductors of insulated cables.

NTP 370.252: Thermoplastic and thermoset insulated cables of rated voltages up to and including 450/750 V.

IEC 60227-5: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Flexible cables (cords).

IEC 60227-1: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - General requirements.

TESTING STANDARDS

IEC 60227-2: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Test methods.

IEC 60332-1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame.

UL 2556: Wire and Cable Test Methods. Section 9.3: FT1 (Vertical-Specimen) Flame Test.

IEC 60811-401: Thermal ageing methods. Ageing in an air oven.

IEC 60811-409: Miscellaneous tests. Mass loss test for thermoplastic insulations and covers.

IEC 60811-504: Tests at low temperature.

IEC 60811-505: Tests at low temperature.

IEC 60811-506: Tests at low temperature.

IEC 60811-508: Pressure test at high temperature for insulation and sheaths.

IEC 60811-509: Test for resistance of insulations and sheaths to cracking.

UL 2556: Wire and Cable Test Methods. Section 4.2.8.5: Carbon-Arc and Xenon-Arc Tests- Sunlight resistance. 

Core Identification I

Number of cores Number of traces on the sheath Core identification
2+T 2

White + Black + yellow

White + Black + green

White + Black + yellow/green

White + Black + green/yellow

3+T 3

White + Black + Red + yellow

White + Black + Red + green

White + Black + Red + yellow/green

White + Black + Red + green/yellow

4+T 4

White + Black + Red + Blue + yellow

White + Black + Red + Blue + green

White + Black + Red + Blue + yellow/green

White + Black + Red + Blue + green/yellow

 

Conductor cross-section identification

Conductor cross-section Conductor cross-section identification - Color of traces
16 AWG Sky blue
14 AWG Orange

 

Calculation of Current Condition L.V.; 70°C

CALCULATION OF CURRENT CONDITION

Maximum conductor temperature : 70°C
Ambient air temperature : 30°C
 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Soft copper
Lead free
Yes
Insulating material
PVC Flexible
Outer sheath
PVC Flexible
Sheath colour
Black
Conductor flexibility
Flexible class 5
Conductor shape
Circular
Insulation colour
White + Black + Red + yellow

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
- mm²
Number of cores
3
Conductor cross-section (AWG/KCMIL)
16 AWG
Wire diameter
0.255 mm
Total number of wires
24
Conductor diameter
1.4 mm
Minimum insulation thickness
0.7 mm
Ground Conductor cross-section (AWG)
16
Minimum Insulation thickness of ground cable
0.7 mm
Minimum outer sheath thickness
1.0 mm
Diameter over Sheath
9.6 mm
Approximate weight
97 kg/km

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
300/500 V
Dielectric strength
2.0 kV
Time of application Dielectric strength core to screen AC
5 min.
Max. DC resistance of the conductor at 20°C
14.4 Ohm/km
Perm current rating in air 30°C
10 A
Nominal phase capacitance
610 µF / km

Mechanical characteristics

Mechanical characteristics

Cable flexibility
Excellent

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2; FT1
Metric marking
Double marking of sequential footage METRIUM
U.V resistance
UL 2556 - Sunlight Resistance
Maximum operating temperature
70 °C
Midspan
Yes
Oil resistance
Good
Reference
01
Overload maximum core temperature
100 °C
Short-circuit max. conductor temperature
160 °C

Resources

Resources

Dealer locator

Waiting…

No items found

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close